Purpose
High current tester HCT-10 (hereinafter the “device’’) is used for testing AC circuit breaker’s efficiency and ampere-second characteristics in 20A - 10kA range, with measuring and registration of time and current values, passing through circuit breaker.; for measuring and protecting transformers tests via primary current; for testing and calibration of current and heat-current relays; fuses testing. The device can be used as regulated current source (10 kA max) for lab operations. Output current-conducting circuits are galvanic coupled with power grid.
Operating conditions:
Ambient temperature range, °С --------------------- -5 – +35
Relative humidity (t=25°С), % -------------------------- £ 80
Atmospheric pressure, mmHg ----------------------------------------- 630 - 800
Specifications:
Source voltage, V* --------------------------------------------------------------380 ±10%
Power grid frequency, Hz ------------------------------------------------------------- 49–60&l
Delivery set:
УПАВ-10М ------------------------------------------------------------------1
Flexible busbar, length - 0,75m, section – 120mm2 --------------